Amp Hours to Watt Hours Calculator
Convert battery charge capacity to nominal and usable energy, with an optional runtime estimate.
Convert battery capacity into stored energy
Amp-hours describe charge capacity, while watt-hours describe energy. Multiplying amp-hours by nominal voltage provides a convenient nominal-energy estimate. Applying a usable percentage can represent discharge limits, inverter losses, temperature effects, and a planning reserve in one combined factor.
Usable watt-hours = nominal watt-hours × usable %
Estimated runtime = usable watt-hours ÷ average load watts
Worked example
A 100 Ah, 12 V battery has 1,200 Wh, or 1.2 kWh, of nominal energy. At an 85% usable factor, the planning estimate is 1,020 Wh. A constant 100 W load would therefore run for about 10.2 hours in the simplified model.
Why actual runtime differs
- Battery voltage changes with state of charge and load; nominal voltage is a label, not a constant measurement.
- Battery chemistry, age, temperature, discharge rate, and manufacturer limits affect usable capacity.
- Inverters and wiring consume energy, and many devices cycle rather than draw a constant load.
- A conservative usable percentage can combine expected losses and reserve, but product-specific data is better.
Frequently asked questions
Can I add amp-hour ratings together?
For identical batteries in parallel, amp-hours add while nominal voltage stays the same. In series, voltage adds while amp-hours stay the same. The batteries and connection must be compatible and safely engineered.
Are watt-hours the same as watts?
No. Watts measure power at a moment; watt-hours measure energy over time. A 100 W load running for two hours uses 200 Wh in the ideal calculation.
What usable percentage should I choose?
Use the battery and system manufacturer’s limits. The default is only an example, not a recommendation for any chemistry or installation.
How to get a dependable result
- Use nameplate ratings or manufacturer specifications when they are available.
- Keep every input in the unit shown beside its field.
- Treat calculated values as planning estimates; real equipment, batteries, and conductors have losses, tolerances, and operating limits.